<?xml version="1.0" encoding="utf-8"?>
<Spec id="480" path="\d\e\de6a24188d801941573e696b5745eb04.pdf"><Text id="84115" page="10">The design, manufacture, performance and testing of Variable Speed Drive (VSD) Controller and Soft Starter shall conform, except where otherwise specified, to the current issues and amendments of the applicable Codes, Standards and Specifications, including but not limited to the following:</Text><Text id="84116" page="11">IEEE 519 IEEE Recommended Practices and Requirements for Harmonic Control in Electrical Power Systems</Text><Text id="84117" page="11">IEEE 1566 Standard for Performance of Adjustable Speed AC Drives Rated 375 kW and Larger</Text><Text id="84119" page="12">In addition to the KOC Standards and Recommended Practices referenced herein, the Controlling Teams in KOC shall designate other relevant project specifications as required including the following: Title / Description 015-HH-1101 HVAC Equipment and Installation</Text><Text id="84120" page="13">The Variable Speed Drive (VSD) Controller and Soft Starter are normally installed in substation / room provided with HVAC System, located adjacent to the driven equipment, unless otherwise specified in the project document / Data Sheet. However, it shall be rated for continuous operation at full load and rated speed under the temperature from -3˚ C to 50˚ C and humidity 100%.</Text><Text id="84271" page="13">6.2.1 Any electrical equipment to be installed in a hazardous area shall conform to the relevant parts of “KOC Recommended Practice for Selection, Installation and Maintenance of Electrical Equipment in Hazardous Areas” (KOC-E-004). 6.2.2 The equipment to be installed in a hazardous area shall be certified for use in those areas by a testing authority of an international recognition. The list of testing and certifying agencies acceptable to KOC are given in KOC-E-004 Part 2. 6.2.3 The copies of hazardous area certification documents shall be submitted to KOC for review and approval.</Text><Text id="84272" page="14">The design of VSD Controller shall conform to the requirements of IEC 61800-4 (for VSD above 1000 V) and IEC 61800-2 (for VSD up to 1000 V).</Text><Text id="84273" page="15">The Vendor / Contractor shall conduct a study for evaluating Harmonics, Power Factor (PF), Short Circuit Current, Motor Starting Parameters etc., prior to finalising the design of VSD Controller systems of drive rated above 120 kW, unless otherwise specified in the project document / Data Sheet.</Text><Text id="84274" page="16">The major components of VSD Controller shall include, but not limited to Converter Unit, Harmonic Filters, Cooling System etc.</Text></Spec>