<?xml version="1.0" encoding="utf-8"?>
<Spec id="480" path="\d\e\de6a24188d801941573e696b5745eb04.pdf"><Text id="84115" page="10">The design, manufacture, performance and testing of Variable Speed Drive (VSD) Controller and Soft Starter shall conform, except where otherwise specified, to the current issues and amendments of the applicable Codes, Standards and Specifications, including but not limited to the following:</Text><Text id="84116" page="11">IEEE 519 IEEE Recommended Practices and Requirements for Harmonic Control in Electrical Power Systems</Text><Text id="84117" page="11">IEEE 1566 Standard for Performance of Adjustable Speed AC Drives Rated 375 kW and Larger</Text><Text id="84119" page="12">In addition to the KOC Standards and Recommended Practices referenced herein, the Controlling Teams in KOC shall designate other relevant project specifications as required including the following: Title / Description 015-HH-1101 HVAC Equipment and Installation</Text><Text id="84120" page="13">The Variable Speed Drive (VSD) Controller and Soft Starter are normally installed in substation / room provided with HVAC System, located adjacent to the driven equipment, unless otherwise specified in the project document / Data Sheet. However, it shall be rated for continuous operation at full load and rated speed under the temperature from -3˚ C to 50˚ C and humidity 100%.</Text><Text id="84271" page="13">6.2.1 Any electrical equipment to be installed in a hazardous area shall conform to the relevant parts of “KOC Recommended Practice for Selection, Installation and Maintenance of Electrical Equipment in Hazardous Areas” (KOC-E-004). 6.2.2 The equipment to be installed in a hazardous area shall be certified for use in those areas by a testing authority of an international recognition. The list of testing and certifying agencies acceptable to KOC are given in KOC-E-004 Part 2. 6.2.3 The copies of hazardous area certification documents shall be submitted to KOC for review and approval.</Text><Text id="84272" page="14">The design of VSD Controller shall conform to the requirements of IEC 61800-4 (for VSD above 1000 V) and IEC 61800-2 (for VSD up to 1000 V).</Text><Text id="84273" page="15">The Vendor / Contractor shall conduct a study for evaluating Harmonics, Power Factor (PF), Short Circuit Current, Motor Starting Parameters etc., prior to finalising the design of VSD Controller systems of drive rated above 120 kW, unless otherwise specified in the project document / Data Sheet.</Text><Text id="84274" page="16">The major components of VSD Controller shall include, but not limited to Converter Unit, Harmonic Filters, Cooling System etc.</Text><Text id="84275" page="16">VSD Controller shall be suitably designed to limit the Total Harmonic Distortion (THD) to comply with the requirements specified in IEEE 519. For any specific applications, where the THD limits needs to be more stringent (For e.g. VSD application in Hospitals), it shall be specifically mentioned in the project document.</Text><Text id="84426" page="16">For safe maintenance of the VSD Controller, suitable measures shall be provided for discharging the static energy in the DC section. The doors of the panel shall be provided with interlock (with time delay) to avoid inadvertent opening of the panel doors until the static energy is completely discharged.</Text><Text id="84427" page="16">Variable Speed Drive (VSD) Controller shall be rated for 100% full load current with Duty Class-II in accordance with IEC 60146.</Text><Text id="84428" page="16">VSD Controller shall be provided with a suitably rated circuit breaker for local isolation of incoming power supply, where specifically called for in the project document / Data Sheet. For details of circuit breakers, KOC-E-002 Pt.1 “KOC Standard for High Voltage Switchgear and Controlgear (1 kV to 11 kV) and KOC-E-009 “KOC Standard for Low Voltage Switchgear” shall be referred, as applicable.</Text><Text id="84429" page="17">Major components of the Converter Unit shall include, but not limited to the following: a) Converter Transformer, b) Rectifier, c) DC Link, d) Inverter, e) Sinusoidal Filter (as required), f) Any other components required for the normal operation of VSD System.</Text><Text id="84430" page="17">To reduce dc voltage / current ripples within the acceptable limits, VSD Controller shall be provided with DC Link, between the input rectifier and output inverter.</Text><Text id="84431" page="18">In order to ensure a smooth sine wave output voltage to the VSD Motor, VSD Controller shall be provided with a Sinusoidal Filter. While designing the Sinusoidal Filter, the following shall be considered: a) Length of output cable from the VSD Drive to Motor, b) Level of Common Mode noise generated by VSD, c) The ability of Motor insulation level to withstand dv/dt.</Text><Text id="84432" page="18">The Vendor / Manufacturer shall provide all accessories required for the complete cooling system, such as cooling fans, air ducting etc.</Text></Spec>