<?xml version="1.0" encoding="utf-8"?>
<Spec id="600" path="\7\3\735df46bff22e75b9395aa7eb3db8436.pdf"><Text id="88051" page="8">The design, performance, manufacture and testing of High Voltage Induction Motors shall conform, except where otherwise specified, with the current issues and amendments of the applicable Codes and Standards, including but not limited to the following:</Text><Text id="88052" page="11">The environmental conditions in Kuwait are severe and shall be considered carefully while selecting High Voltage Induction Motors used for outdoor installation. The High Voltage Induction Motors intended for outdoor installation shall be suitable for continuous operation at a desert location under high ambient temperature and humidity. The atmosphere shall be considered to be dusty, corrosive and may contain traces of Hydrogen Sulphide (H 2 S), SO x / NO x gases and airborne chemical contaminants.</Text><Text id="88053" page="8">4.2 List of Standards, Codes and Specifications The design, performance, manufacture and testing of High Voltage Induction Motors shall conform, except where otherwise specified, with the current issues and amendments of the applicable Codes and Standards, including but not limited to the following:</Text><Text id="88054" page="11">5.0 ENVIRONMENTAL CONDITIONS 5.1 The environmental conditions in Kuwait are severe and shall be considered carefully while selecting High Voltage Induction Motors used for outdoor installation. The High Voltage Induction Motors intended for outdoor installation shall be suitable for continuous operation at a desert location under high ambient temperature and humidity. The atmosphere shall be considered to be dusty, corrosive and may contain traces of Hydrogen Sulphide (H 2 S), SO x / NO x gases and airborne chemical contaminants.</Text><Text id="88055" page="13">8.2 Motor Windings 8.2.1 The stator winding of the motor shall be Copper. The winding shall be adequately supported, braced and blocked to provide sufficient rigidity during normal operating conditions. The bracing shall be adequate enough to withstand Direct-On-Line (DOL) starting and re-switching at a value of residual voltage of at least 30 % of rated voltage and 180° out of phase with the supply voltage. Bracing shall be capable of preventing the resonant vibration of over hung end- windings.</Text><Text id="88056" page="16">12.0 BEARINGS 12.1 The bearings (Ball / Roller / Sleeve types) used in motors shall be suitable for the applications / type of driven equipment. The driven equipment Manufacturer shall provide the normal thrust exerted by the drive / load in order to design the type of bearing. For guidance on selection of bearings, API 541 shall be referred.</Text><Text id="88057" page="16">The maximum permitted noise level shall be 81 dB(A) at a reference distance of one (1) metre with the motor operating at no-load, rated voltage and frequency.</Text><Text id="88058" page="23">List of Spare Parts for two (2) years of Normal Operation,</Text><Text id="88059" page="21">List of Spare Parts for minimum two (2) years of Normal Operation,</Text><Text id="88060" page="8">List of Standards, Codes and Specifications The design, performance, manufacture and testing of High Voltage Induction Motors shall conform, except where otherwise specified, with the current issues and amendments of the applicable Codes and Standards, including but not limited to the following:</Text><Text id="88061" page="11">5.1 The environmental conditions in Kuwait are severe and shall be considered carefully while selecting High Voltage Induction Motors used for outdoor installation. The High Voltage Induction Motors intended for outdoor installation shall be suitable for continuous operation at a desert location under high ambient temperature and humidity. The atmosphere shall be considered to be dusty, corrosive and may contain traces of Hydrogen Sulphide (H 2 S), SO x / NO x gases and airborne chemical contaminants.</Text><Text id="88062" page="14">The starting current of the motor shall not exceed six (6) times full load current, unless otherwise specified in the Project documents / Datasheets.</Text><Text id="88063" page="16">14.0 NOISE LIMITS The maximum permitted noise level shall be 81 dB(A) at a reference distance of one (1) metre with the motor operating at no-load, rated voltage and frequency.</Text><Text id="88065" page="1">KOC STANDARD FOR HIGH VOLTAGE INDUCTION MOTORS</Text><Text id="88066" page="1">DOC. NO. KOC-E-001 (REV. 3)</Text><Text id="88068" page="2">DOC. NO. KOC-E-001 Page 1 of 27 Rev. 3</Text><Text id="88069" page="2">~,..s:.srJ~&apos;~~~L.....S&apos;~.s&apos;-&quot;&quot;~ A Subsidiary of Kuwart Petroleum Corporation</Text><Text id="88071" page="2">KOC STANDARD FOR HIGH VOLTAGE INDUCTION MOTORS</Text><Text id="88076" page="5">This document “KOC Standard for High Voltage Induction Motors” (KOC-E-001, Rev. 3) is intended to provide the minimum requirements for high voltage induction motors for installation at various KOC Facilities within Kuwait. The earlier document KOC-E-001 (Rev. 2) issued in February 1994 has been substantially revised for conformance with the revisions of relevant International / National Standards and incorporation of latest technological developments in this field.</Text><Text id="88077" page="5">This Standard has been approved by the Standards Team in consultation with the Standards Technical Committee (STC) for use throughout the Engineering and Operational Functions of Kuwait Oil Company (K.S.C.).</Text><Text id="88078" page="5">This Standard sets out to achieve the following objectives:</Text><Text id="88079" page="5">a) To provide technical guidance and establish the base document for developing project / material specifications for High Voltage Induction Motors with a view to achieve uniformity, quality, reliability and efficiency in an economical manner.</Text><Text id="88080" page="5">b) To set out minimum features required, a Datasheet has been included which will act as a checklist to ensure that all requirements for the proper design, construction and operation of High Voltage Induction Motors are covered.</Text><Text id="88081" page="5">c) To maintain the Health, Safety &amp; Environment (HSE) Management, including Process Safety Management (PSM) requirements for the safety and protection of personnel, environment and assets.</Text><Text id="88082" page="5">Feedback as well as any comments or suggestions derived from the application of this Standard at any stage of installation and testing are invited and should be directed to:</Text><Text id="88084" page="6">1.1 This Standard is intended to provide the minimum requirements for the design, manufacture, inspection &amp; factory testing of High Voltage Induction Motors operating at voltages above 1000 V upto and including 11 kV for use in various KOC Facilities within Kuwait.</Text><Text id="88085" page="6">1.2 Motors for special applications such as downhole duties, totally submerged or with hollow shafts are not covered in this Standard.</Text><Text id="88086" page="6">2.1 The design, construction, performance, inspection and testing of High Voltage Induction Motors shall fully comply with all the relevant requirements specified in this Standard and the reference Standards / Codes mentioned herein. Specific requirements, if any, shall be indicated in the Project Documents / Datasheet.</Text><Text id="88087" page="6">2.2 Any exceptions or deviations from this Standard, along with their merits and justifications, shall be brought to the attention of KOC Controlling Team for their review, consideration and amendment by Standards Team (if required).</Text><Text id="88088" page="6">2.3 Compliance of this KOC Standard does not of itself confer immunity from legal or statutory obligations.</Text><Text id="88089" page="6">3.0 TERMINOLOGY 3.1 Definitions For the purpose of this Standard, the following definitions apply:</Text><Text id="88090" page="6">3.1.1 Cage Induction Motor An induction motor with secondary cage (squirrel cage) winding(s).</Text><Text id="88091" page="6">Polarisation index is the quotient of the insulation resistance measured at two (2) different times, usually t1 = 1 min and t10 = 10 min after application of the direct voltage. This is an indicator of the condition of the insulation.</Text><Text id="88092" page="6">An insulation system, the components of which are impregnated under vacuum after complete assembly and connection of the winding.</Text><Text id="88093" page="7">3.2 Abbreviations For the purpose of this Standard, the following abbreviations apply: API American Petroleum Institute BS British Standards DE Drive End FAT Factory Acceptance Test</Text><Text id="88095" page="7">HAC Hazardous Area Classification HSE Health, Safety and Environment HSEMS Health, Safety and Environment Management System HSSE Health, Safety, Security and Environment IEC International Electrotechnical Commission IP Ingress Protection ISO International Organisation for Standardisation ITP Inspection and Test Plan KOC Kuwait Oil Company (K.S.C.) NDE Non-Drive End NFPA National Fire Protection Association</Text><Text id="88097" page="7">PF Power Factor PSM Process Safety Management QA / QC Quality Assurance / Quality Control RTD Resistance Temperature Detector</Text><Text id="88100" page="8">In the event of conflict between this KOC Standard and the latest editions of Standards / Codes referred herein, or other purchase or contractual requirements, the most stringent requirement shall apply.</Text><Text id="88101" page="8">IEC 60034 Rotating Electrical Machines (Various Parts)</Text><Text id="88102" page="8">IEC 60072 Dimensions and Output Ratings of Rotating Machines (Various Parts)</Text><Text id="88103" page="8">IEC 60079 Explosive Atmospheres (Various Parts)</Text><Text id="88104" page="8">IEC 60085 Electrical Insulation - Thermal Evaluation and Designation</Text><Text id="88105" page="8">IEC 60529 Specification for Degrees of Protection provided by Enclosures (IP Code)</Text><Text id="88106" page="8">IEC 60644 Specification for High-Voltage Fuse-Links for Motor Circuit Applications</Text><Text id="88107" page="8">IEC 61000 Electromagnetic Compatibility (EMC) (Various Parts)</Text><Text id="88108" page="8">IEC 62444 Cable Glands for Electrical Installations</Text><Text id="88109" page="8">IEEE 43 Recommended Practice for Testing Insulation Resistance of Rotating Machinery</Text><Text id="88110" page="8">IEEE 112 IEEE Standard Test Procedure for Polyphase Induction Motors and Generators</Text><Text id="88111" page="8">IEEE 841 Standard for Petroleum and Chemical Industry - Premium-Efficiency, Severe-Duty, Totally Enclosed Fan-Cooled (TEFC) Squirrel Cage Induction Motors - Up to and Including 370 kW (500 hp)</Text><Text id="88112" page="8">ISO 281 Rolling Bearings - Dynamic Load Ratings and Rating Life</Text><Text id="88113" page="9">ISO 2954 Mechanical Vibration of Rotating and Reciprocating Machinery - Requirements for Instruments for Measuring Vibration Severity</Text><Text id="88114" page="9">ISO 9000 Quality Management Systems Series of Standards</Text><Text id="88115" page="9">ISO 10285 Rolling bearings - Sleeve Type Linear Ball Bearings - Boundary Dimensions and Tolerances</Text><Text id="88116" page="9">ISO 10817-1 Rotating Shaft Vibration Measuring Systems - Part 1: Relative and Absolute Sensing of Radial Vibration</Text><Text id="88117" page="9">ISO 13012 Rolling Bearings - Accessories for Sleeve Type Linear (Various Parts) Ball Bearings</Text><Text id="88118" page="9">ISO 12944 Paints and Varnishes. Corrosion Protection of Steel (Various Parts) Structures by Protective Paint Systems</Text><Text id="88119" page="9">API STD 541 Form-wound Squirrel Cage Induction Motors - 375 kW (500 Horsepower) and Larger</Text><Text id="88120" page="9">API STD 547 General Purpose Form-wound Squirrel Cage Induction Motors - 185 kW (250 hp) through 2240 kW (3000 hp)</Text><Text id="88121" page="9">API STD 670 Machinery Protection Systems</Text><Text id="88122" page="9">BS 4999 General requirements for Rotating Electrical Machines</Text><Text id="88123" page="9">NFPA 70E Standard for Electrical Safety in Workplace</Text><Text id="88124" page="9">NFPA 70EH Handbook for Electrical Safety in the Workplace</Text><Text id="88125" page="9">KOC-E-002 KOC Standard for High Voltage Switchgear</Text><Text id="88126" page="9">KOC-E-003 Part 1 KOC Recommended Practice for Design Basis and Selection of Electrical Systems</Text><Text id="88127" page="9">KOC-E-003 Part 2 KOC Recommended Practice for Installation and Testing of Electrical Equipment</Text><Text id="88128" page="9">KOC-E-004 KOC Recommended Practice for Selection, (Parts 1-6) Installation and Maintenance of Electrical</Text><Text id="88129" page="9">Equipment in Hazardous Areas</Text><Text id="88130" page="9">KOC-E-006 KOC Recommended Practice for Power System Studies, Protection and Control</Text><Text id="88131" page="10">KOC-E-008 KOC Recommended Practice for Selection and Installation of Electric Cables</Text><Text id="88132" page="10">KOC-E-009 KOC Standard for Low Voltage Switchgear</Text><Text id="88133" page="10">KOC-E-014 KOC Standard for Variable Speed Drive (VSD) Controller and Soft Starter</Text><Text id="88134" page="10">KOC-E-023 KOC Standard for Electric Cables</Text><Text id="88135" page="10">KOC-E-024 KOC Recommended Practice for Earthing and Bonding</Text><Text id="88136" page="10">KOC-G-002 KOC Standard for Hazardous Area Classifications</Text><Text id="88137" page="10">KOC-G-004 KOC Standard for Packing, Marking and Documentation</Text><Text id="88138" page="10">KOC-G-007 KOC Standard for Basic Design Data</Text><Text id="88139" page="10">KOC-G-009 KOC Standard for Spare Parts and Maintenance Data</Text><Text id="88140" page="10">KOC-ME-006 Part 2 KOC Standard for Reciprocating Pumps</Text><Text id="88141" page="10">KOC-ME-006 Part 3 KOC Standard for Positive Displacement Pumps - Rotary</Text><Text id="88142" page="10">KOC-ME-008 Part 2 KOC Standard for Centrifugal Pumps</Text><Text id="88143" page="10">KOC-ME-008 Part 3 KOC Standard for Horizontal End Suction Centrifugal Pumps to ASME B73.1</Text><Text id="88144" page="10">KOC-ME-011 KOC Standard for Process Gas Centrifugal Compressors</Text><Text id="88145" page="10">KOC-P-001 KOC Standard for Painting and Coating of External Metal Surfaces</Text><Text id="88146" page="10">KOC-Q-014 KOC Standard for Project QA / QC General Requirements</Text><Text id="88148" page="10">KOC.SA.027 Electrical Work Safety Procedure</Text><Text id="88149" page="10">KOC.SA.022 Electrical Multi-Lockout and Tagout Procedure</Text><Text id="88150" page="10">KOC.PS.001 Process Safety Management Manual</Text><Text id="88151" page="10">KOC.PS.006 Procedure for Inherently Safer Design (ISD)</Text><Text id="88152" page="11">5.1 The environmental conditions in Kuwait are severe and shall be considered carefully while selecting High Voltage Induction Motors used for outdoor installation. The High Voltage Induction Motors intended for outdoor installation shall be suitable for continuous operation at a desert location under high ambient temperature and humidity. The atmosphere shall be considered to be dusty, corrosive and may contain traces of Hydrogen Sulphide (H 2</Text><Text id="88157" page="11">5.2 For detailed information regarding the environmental, site and utility supply conditions prevailing throughout the KOC Facilities, KOC-G-007 “KOC Standard for Basic Design Data” shall be referred.</Text><Text id="88158" page="11">6.1.1 The High Voltage Induction Motors are normally installed outdoor provided with shelters and shall be suitable for environmental conditions in Kuwait for operation under the temperature from -3 ˚C to 50 ˚C &amp; humidity up to 100 %. In cases where any motor is to be installed in ambient temperature higher than stated above, it shall be specified in the Project Documents / Datasheet.</Text><Text id="88159" page="11">6.1.2 The Manufacturer / Vendor of High Voltage Induction Motors shall confirm that motors typical of that being supplied have been in operational use without problems, elsewhere under similar service / environmental conditions and reliability of all components in the motors to perform continuously in the service condition specified is guaranteed.</Text><Text id="88160" page="11">6.2.1 The classification of hazardous areas shall be based on the requirements of KOC-G-002 &quot;KOC Standard for Hazardous Area Classification&quot; and the latest edition of relevant International / National Standards / RPs / Code of Practices. For Hazardous Area Classification (HAC) of existing KOC Operating Facilities, KOC’s HAC drawings of the relevant Facility shall be referred.</Text><Text id="88161" page="11">6.2.2 The motor and accessories to be installed in a hazardous area shall be certified for use in those areas by a testing authority of an International recognition. The list of testing and certifying bodies acceptable to KOC are given in KOC-E-004 Part 2 “KOC Recommended Practice for Selection, Installation and Maintenance of Electrical Equipment in Hazardous Areas, (Flameproof Enclosure ‘d’)”.</Text><Text id="88162" page="11">6.2.3 The copies of hazardous area certification documents shall be submitted to KOC for review and approval.</Text><Text id="88163" page="11">6.2.4 The type of protection of motor required for a particular application shall depend on the Hazardous Area Classification as indicated in Project Documents / Datasheet.</Text><Text id="88164" page="12">6.2.5 The motors to be used in Hazardous Areas Zone 1 and Zone 2 shall be flameproof enclosure type Ex “d” certified in accordance with the requirements of IEC 60079-1. In case, where large capacity Ex “d” certified motors are not in the production range of Manufacturers for a particular application, Ex “p” certified motors in accordance with the requirements of IEC 60079-2 shall be considered with prior approval from KOC.</Text><Text id="88165" page="12">6.2.6 The maximum surface temperature of the motor to be used in Hazardous Area shall not exceed the limits of 200 °C (rating of Temperature Class T3) for normal applications in KOC. In cases where the motor to be installed in a more stringent hazardous area (with lesser ignition temperature of gas / vapour), it shall be specified in the Project Documents / Datasheet.</Text><Text id="88166" page="12">7.1 All applicable HSE requirements as per the relevant International and National Standards shall be considered in the design, material selection and manufacture of the High Voltage Induction Motors. Any material containing asbestos shall not be used in the motors / accessories.</Text><Text id="88167" page="12">7.2 Relevant KOC HSE requirements, including the Process Safety Management (PSM) requirements and specifically the Procedure for Inherently Safer Design (ISD) shall be adhered to while designing, engineering and material selection of HV Induction Motors so as to safeguard personnel, environment and assets during the use of motors.</Text><Text id="88168" page="12">7.3 The Manufacturer shall provide KOC with all relevant HSE information and precautionary measures, including Safety Manual(s) pertaining to the handling, operation and maintenance of motors.</Text><Text id="88169" page="12">8.1.1 The High Voltage Cage Induction Motors shall be designed and manufactured in accordance with requirements specified in IEC 60034 (Relevant Parts).</Text><Text id="88170" page="12">8.1.2 The motor design shall be suitable for operation under a frequency variation of -5 % to +2.5 % of the nominal frequency and voltage variation of ± 6 % of rated voltage.</Text><Text id="88171" page="12">8.1.3 The ratings of induction motors at 3.3 kV shall be limited to 1200 kW and above 1200 kW, it shall be of 11 kV rating for all normal applications.</Text><Text id="88172" page="12">8.1.4 Where other voltage / frequency ratings are required for any particular applications such as VSD motors, the voltage / frequency ratings shall be specified in the Project Documents / Datasheet or approved by KOC.</Text><Text id="88173" page="12">8.1.5 For details of Voltage, Frequency and Phase Sequence prevailing in various KOC Facilities, refer to KOC-E-003 Part 1 “KOC Recommended Practice for Design Basis and Selection of Electrical Systems”.</Text><Text id="88174" page="13">8.1.6 The induction motors shall be three-phase cage induction type, rated for a single voltage suitable for operation on voltage, frequency, load characteristics, operational duty etc. as specified in the Project Documents / Datasheet.</Text><Text id="88175" page="13">8.1.7 The motor shall be of rugged cast iron / sheet steel construction for using in toughest environmental conditions as specified in Clause 5.0 of this Standard. The material of construction of rotor bars shall be Copper.</Text><Text id="88176" page="13">8.1.8 The Ingress Protection (IP) rating of motor and terminal boxes shall be as specified in the Project Documents / Datasheet. For details of minimum degree of ingress protection requirements for electrical equipment, KOC-E-003 Part 1 “KOC Recommended Practice for Design Basis and Selection of Electrical Systems” shall be referred.</Text><Text id="88177" page="13">8.1.9 The motors in Hazardous Area shall be certified for use in such areas in accordance with the requirements of IEC 60079 (Relevant Parts). For details of Hazardous Area Classification and Certification, Sub-Clause 6.2 of this Standard shall be referred.</Text><Text id="88178" page="13">8.1.10 The Efficiency and Power Factor (PF) of motors shall be as specified in the Project Documents / Datasheet. The minimum efficiency and power factor of the motor shall be 90 % and 0.9 (lagging) respectively, unless otherwise specified in the Project Documents / Datasheet.</Text><Text id="88179" page="13">8.1.11 For specific requirements of motors for VSD Systems, KOC-E-014 “KOC Standard for Variable Speed Drive (VSD) Controller and Soft Starter” shall be referred.</Text><Text id="88180" page="13">8.2.1 The stator winding of the motor shall be Copper. The winding shall be adequately supported, braced and blocked to provide sufficient rigidity during normal operating conditions. The bracing shall be adequate enough to withstand Direct-On-Line (DOL) starting and re-switching at a value of residual voltage of at least 30 % of rated voltage and 180° out of phase with the supply voltage. Bracing shall be capable of preventing the resonant vibration of over hung end- windings.</Text><Text id="88181" page="13">8.2.2 The motor winding shall be star connected and all the six winding leads shall be brought out to the terminal box, unless otherwise specified in the Project Documents / Datasheet.</Text><Text id="88182" page="13">8.2.3 In case of vertical motors &quot;winding support&quot; shall prevent any dropping or permanent displacement of windings.</Text><Text id="88183" page="13">8.2.4 The insulation of winding shall be Class &apos;F&apos; and the temperature rise of the motor shall not exceed to that applicable to Class &apos;B&apos; insulation, unless otherwise specified in the Project Documents / Datasheet.</Text><Text id="88184" page="13">8.2.5 Impulse voltage withstand levels of stator windings shall be in accordance with the requirements of IEC 60034-15.</Text><Text id="88185" page="14">8.2.6 Winding insulation shall be non-hygroscopic and oil resistant. The windings shall be vacuum-pressure impregnated and suitably processed to effectively seal them to prevent deterioration during adverse environmental and operational conditions.</Text><Text id="88186" page="14">8.3.1 Motors shall be suitable for &quot;Direct-On-line (DOL)” starting and shall be of Type-S1 (Continuous Duty), unless otherwise specified in the Project Documents / Datasheet.</Text><Text id="88187" page="14">8.3.2 Motors for normal applications shall be capable of two (2) successive direct-on-line load-coupled starts repeated at 20 minutes interval at normal running temperature within the Temperature Class T3. Any other specific starting requirements for a particular application shall be specified in the Project Documents / Datasheet.</Text><Text id="88188" page="14">8.3.3 The motor shall be designed capable of starting and accelerating the connected load to running speed with 80 % of rated voltage at the motor terminals.</Text><Text id="88189" page="14">8.3.4 The starting current of the motor shall not exceed six (6) times full load current, unless otherwise specified in the Project documents / Datasheets.</Text><Text id="88190" page="14">9.1 All motors shall be provided with at least six (6) nos. of embedded (simplex) Resistance Temperature Detectors (RTDs), two (2) per phase, for monitoring stator winding temperature, unless otherwise specified in the Project Documents / Datasheet.</Text><Text id="88191" page="14">9.2 All motors shall be provided with two (2) nos. of simplex RTD type bearing temperature detectors per bearing unless otherwise specified in the Project Documents / Datasheet. Local bearing temperature indicators shall be provided for 11 kV motors.</Text><Text id="88192" page="14">9.3 The Resistance Temperature Detectors (RTDs) shall be of Platinum (Pt100), three (3) lead type, unless otherwise specified in the Project Documents / Datasheet. All embedded temperature detectors in a motor shall have same characteristics.</Text><Text id="88193" page="14">9.4 The temperature detectors shall be wired to a separate independent terminal box.</Text><Text id="88194" page="14">9.5 Any indicating instruments, alarm and / or other devices as applicable / as specified in the Project Documents / Datasheet shall also be provided separately for local measurements.</Text><Text id="88195" page="14">10.0 TERMINAL BOXES 10.1 Motor terminal boxes shall conform to the requirements specified in IEC 60034-7.</Text><Text id="88196" page="14">10.2 Main terminal box for power cables shall be provided on the side (Left or Right viewed from DE) of the motor as specified in the Project Documents / Datasheet, to suit the driven equipment.</Text><Text id="88197" page="15">10.3 A separate terminal box for differential protection current transformer shall be provided on the opposite side of power cable terminal box, where required. Motors of rating 1200 kW and above shall be provided with differential protection, unless otherwise specified in the Project Documents / Datasheet.</Text><Text id="88198" page="15">10.4 The terminal box shall be suitably sized with provision for interchanging of any two (2) core connections at the terminal box, without stressing the connections, to facilitate correction of direction of rotation of the motor. The terminal box for power cables shall be designed such that it can be turned by 90° positions to suit cable entry, as per site conditions.</Text><Text id="88199" page="15">10.5 Separate terminal boxes shall be provided for instrument cables (temperature detectors, vibration sensors etc.), anti-condensation heater cables etc., as applicable. Each of these terminal boxes shall be provided with an internal earth terminal and shall be protected against over-voltage.</Text><Text id="88200" page="15">10.6 The Hazardous Area Certification for terminal boxes shall be of the same type as for the motor.</Text><Text id="88201" page="15">10.7 The main terminal box for power cables shall be capable of withstanding pressure build-up resulting from a three phase fault conditions without danger to personnel and plant.</Text><Text id="88202" page="15">10.8 The spare cable entry holes in the terminal boxes, if any, shall be sealed using appropriate type of certified plugs that maintain the same type / degree of protection of the terminal box to prevent the entry of hazardous gases / ingress of water.</Text><Text id="88203" page="15">10.9 To prevent moisture entry into the windings during transportation and storage of motors, the terminal boxes shall be provided with desiccant, while delivery of motors.</Text><Text id="88204" page="15">10.10 The terminals / phase sequence shall be marked in accordance with the requirements of IEC 60034-8, unless otherwise specified in the Project Documents / Datasheet.</Text><Text id="88205" page="15">11.1 The motor shall be air cooled with fans fitted to the rotor shaft at Non-Drive End (NDE) for providing cooling air flow in the direction of the driven equipment, unless otherwise specified in the Project Documents / Datasheet.</Text><Text id="88206" page="15">11.2 Fan blades and housings shall be designed and constructed to prevent sparking due to any mechanical contact during operation. Fan shall be of non-corroding metal construction treated with corrosion-resistant coating.</Text><Text id="88207" page="15">11.3 Where heat exchangers are required for cooling large capacity motors, air-to-air heat exchanger shall be used.</Text><Text id="88208" page="16">12.1 The bearings (Ball / Roller / Sleeve types) used in motors shall be suitable for the applications / type of driven equipment. The driven equipment Manufacturer shall provide the normal thrust exerted by the drive / load in order to design the type of bearing. For guidance on selection of bearings, API 541 shall be referred.</Text><Text id="88209" page="16">12.2 The horizontal motor shall have two (2) ball / roller bearings, grease packed and sealed for life to prevent the ingress of foreign matter and the loss of grease. Where high radial forces occur in service, the combination of ball and roller bearing shall be suitably used.</Text><Text id="88210" page="16">12.3 Vertical motors shall have thrust bearings designed to carry the maximum axial thrust (up and down) imposed by the driven equipment.</Text><Text id="88211" page="16">12.4 The bearings shall be in metric sizes and comply with International Organization for Standardization (ISO) recommended dimensions.</Text><Text id="88212" page="16">12.5 The bearing design shall provide sufficient damping to minimise the rotor vibration.</Text><Text id="88213" page="16">12.6 For oil lubricated sleeve bearings, necessary instruments for measuring lube oil level, flow, pressure and temperature shall be provided, as required.</Text><Text id="88214" page="16">13.1 Motors with rating of 750 kW and above shall be equipped with vibration monitoring equipment at each bearing, unless otherwise specified in the Project Documents / Datasheet.</Text><Text id="88215" page="16">13.2 The vibration monitoring equipment shall be non-contacting proximity probes complying with the requirements of API 670.</Text><Text id="88216" page="16">13.3 The limits of vibration shall conform to the requirements specified in IEC 60034-14, unless otherwise specified in the Project Documents / Datasheet.</Text><Text id="88217" page="16">15.1 Grease lubricated bearing shall have pressure relief devices, which ensure that the new grease displaces the maximum amount of old grease and ejects the surplus grease outside the motor.</Text><Text id="88218" page="16">15.2 Re-lubrication shall be possible on both oil or grease type bearings without stopping or dismantling the motor in a safe manner.</Text><Text id="88219" page="17">16.1 The motors shall be provided with a suitably rated anti-condensation heaters. The anti-condensation heaters shall be suitable for operation on a single phase, 50 Hz, 250 V AC supply, unless otherwise specified in the Project Documents / Datasheet.</Text><Text id="88220" page="17">16.2 The anti-condensation heater shall be of fully insulated design and shall be suitably arranged to provide uniform heating to the stator.</Text><Text id="88221" page="17">16.3 It shall be ensured that the motor surface temperature shall not exceed the specified limiting temperature of the motor, when the anti-condensation heater is “ON”.</Text><Text id="88222" page="17">16.4 Anti-condensation heaters of the motors shall be provided with interlocks in such a way that heaters shall be automatically “ON” when power supply to the motor is “OFF” and vice versa.</Text><Text id="88223" page="17">16.5 A warning label shall be provided to indicate that the “Heater Circuit will be ON when the motor is stationary”.</Text><Text id="88224" page="17">17.1 Motors shall be provided with minimum two (2) separate earthing terminals on the frame, suitably marked with the Earthing symbol, for providing connections to the earth grid.</Text><Text id="88225" page="17">17.2 The earthing terminal shall be suitably sized to accommodate an earthing conductor of cross-sectional area as specified in the Datasheet.</Text><Text id="88226" page="17">18.1 The motors shall be provided with suitable lifting / handling arrangements and suitably arranged jacking points in all three planes, easily identified on the motor and shown in the equipment drawings.</Text><Text id="88227" page="17">18.2 Where it is intended to use spreader bars for lifting all or part of machine or where special handling precautions are necessary, it shall be indicated on a suitable plate affixed to the external surface of the motor.</Text><Text id="88228" page="17">19.1 All motors shall be painted in grey colour, unless otherwise specified in the Project Documents / Datasheet.</Text><Text id="88229" page="17">19.2 The paint shall withstand salt laden atmosphere with good resistant quality against acid, alkaline and high temperatures.</Text><Text id="88230" page="17">19.3 For details of painting requirements, KOC-P-001 &quot;KOC Standard for Painting and Coating of External Metal Surfaces” shall be referred.</Text><Text id="88231" page="18">20.1 Nameplate shall be made of stainless steel and be screw fixed to a non-removable part of the motor frame and shall be stamped with data in accordance with IEC 60034-1. Values given shall be those measured during tests. The information to be given on the nameplate shall include, but not limited to the following:</Text><Text id="88232" page="18">a) Manufacturer’s Name and Country of Manufacture,</Text><Text id="88233" page="18">b) Serial Number / Frame Size / Year of Manufacture,</Text><Text id="88234" page="18">c) Enclosure Degree of Protection (IP Code),</Text><Text id="88235" page="18">d) Hazardous Area Certification / Temperature Class / Gas Group,</Text><Text id="88237" page="18">f) Insulation Class / Type,</Text><Text id="88238" page="18">g) Winding Connection / Phase Sequence,</Text><Text id="88239" page="18">h) Rated Output in kW,</Text><Text id="88240" page="18">i) Rated Voltage in kV,</Text><Text id="88241" page="18">j) Rated Current in Amps,</Text><Text id="88242" page="18">k) Rated Frequency in Hz,</Text><Text id="88243" page="18">l) Rated Power Factor (Cos Ø),</Text><Text id="88245" page="18">n) Rated Speed in RPM,</Text><Text id="88246" page="18">o) Bearing Type / Details,</Text><Text id="88247" page="18">p) Lubrication Information (as applicable),</Text><Text id="88248" page="18">q) Rated Noise Level in dB(A),</Text><Text id="88250" page="18">s) Anti-Condensation Heater Voltage and Power,</Text><Text id="88252" page="18">u) Any other information required as specified in the Project Documents / Datasheet or recommended by Manufacturer.</Text><Text id="88253" page="18">20.2 The direction of rotation of the motor shall be clearly indicated on the motor by raised or embossed markings.</Text><Text id="88254" page="19">21.1.1 All motors shall be subjected to tests at the Manufacturer&apos;s Works as per this Standard and relevant International / National Standards.</Text><Text id="88255" page="19">21.1.2 The Manufacturer shall submit the Inspection &amp; Test Plan (ITP) and Factory Test Procedures to KOC for review / approval.</Text><Text id="88256" page="19">21.2.1 The inspection, tests and measurements on HV Induction Motors shall be carried out at Manufacturer’s Facility in accordance with the approved FAT Procedures / ITP. The inspection, tests and measurements to be carried out shall include but not limited to the following:</Text><Text id="88260" page="19">d) Measurement of Winding Resistance (Cold and Hot),</Text><Text id="88261" page="19">e) Measurement of No Load Losses and Current,</Text><Text id="88262" page="19">f) Measurement of Slip at ¾ Load and Full Load,</Text><Text id="88263" page="19">g) Measurement of Vibration,</Text><Text id="88264" page="19">h) Measurement of Winding and Bearing Temperature,</Text><Text id="88265" page="19">i) Measurement of Lube Oil Level / Pressure / Temperature (as applicable),</Text><Text id="88266" page="19">j) Measurement of Noise,</Text><Text id="88267" page="19">k) Measurement of Parameters and Calculation of Locked Rotor Current and Torque,</Text><Text id="88268" page="19">l) Measurement of Parameters and Calculation of Pull-Up Torque,</Text><Text id="88269" page="19">m) Measurement of Parameters and Calculation of Starting Torque Characteristic,</Text><Text id="88270" page="19">n) Measurement of Parameters and Calculation of Efficiency at Full Load, Three-Quarters and Half Load,</Text><Text id="88271" page="19">o) Measurement of Parameters and Calculation of Power Factor at Full Load, Three-Quarters and Half Load,</Text><Text id="88272" page="19">p) High Voltage Test plus Insulation Resistance Test before and after Heat Run Test,</Text><Text id="88273" page="20">q) Determination of Polarisation Index on stator windings,</Text><Text id="88274" page="20">r) Partial Discharge Test on 11 kV motors,</Text><Text id="88275" page="20">s) High Voltage and Continuity Tests on Embedded Temperature Detectors with Tests to Demonstrate Satisfactory Operation and Compliance with Stated Characteristics,</Text><Text id="88276" page="20">t) Direction of Rotation and Phase Sequence Checks,</Text><Text id="88277" page="20">u) Inspection (at full load) of Bearings and Mechanical Operation of the Motor,</Text><Text id="88278" page="20">v) Full Load Heat Run Test (carried out at least on one machine of each group of identical machines being supplied, unless otherwise specified in the Project Documents / Datasheet),</Text><Text id="88279" page="20">w) Momentary Overload Test,</Text><Text id="88280" page="20">x) Painting Colour and Thickness Checking,</Text><Text id="88281" page="20">y) Any other tests as specified in the Project Documents / Datasheet. Note: For additional tests of VSD Motors, “KOC-E-014” shall be referred.</Text><Text id="88282" page="20">21.2.2 Test Reports / Certificates along with relevant documents for all motors shall be submitted to KOC for review and approval. The motors shall not be delivered to KOC until all applicable tests have been successfully completed and test reports approved by KOC.</Text><Text id="88283" page="20">21.2.3 For installation and site testing requirements of motors, KOC-E-003 Part 2 “KOC Recommended Practice for Installation and Testing of Electrical Equipment” shall be referred.</Text><Text id="88284" page="20">22.1 The Manufacturer / Vendor shall operate a quality system to ensure that the requirements of this Standard are achieved. The Manufacturer’s quality system shall be preferably based on ISO 9000 Series of Standards, certified by Internationally Accredited Certification Bodies.</Text><Text id="88285" page="20">22.2 Verification of the Manufacturer / Vendor quality system is normally part of the pre-qualification procedure and therefore not detailed in this Standard.</Text><Text id="88286" page="20">22.3 For details of quality requirements, KOC-Q-014 “KOC Standard for Project QA / QC General Requirements” shall be referred.</Text><Text id="88287" page="20">23.1 All Correspondences, Drawings, Catalogues, Instruction Manuals, Datasheets or any other written information shall be in the English language. In case of dual languages, one (1) language shall be English.</Text><Text id="88288" page="21">23.2 All dimensions, units of measurement, physical constants etc. shall be in SI units, unless otherwise specified in the Project Documents.</Text><Text id="88289" page="21">23.3 All documents submitted by the Manufacturer / Vendor shall be marked with relevant Purchase Order Number, Project / Contract Number and Manufacturer’s Reference Number for ease of tracking. In addition to the hard copies, electronic files of all documents, datasheets, drawings etc. shall be provided in software approved by KOC.</Text><Text id="88290" page="21">23.4 The documents / drawings of HV Induction Motors to be provided by the Vendor / Manufacturer while submitting the offer for review and approval shall include but not limited to the following:</Text><Text id="88291" page="21">a) Manufacturer’s Name and Address,</Text><Text id="88293" page="21">c) General arrangement drawings with Dimensions, Weight and all other details such as Arrangement of Terminal Boxes, Lifting Points etc. (as applicable),</Text><Text id="88294" page="21">d) Mounting Dimensions with Fixing Details,</Text><Text id="88297" page="21">g) Terminal Boxes - Dimensional Details,</Text><Text id="88298" page="21">h) Cable Termination and Entry Positions Details,</Text><Text id="88300" page="21">j) Minimum Clearance Requirements for Maintenance,</Text><Text id="88301" page="21">k) Type Test Certificates,</Text><Text id="88302" page="21">l) Inspection and Test Plan (ITP),</Text><Text id="88303" page="21">m) Details of Temperature Detectors and other Instrumentation sensors / items with all technical details, Type, Serial Number etc. (as applicable),</Text><Text id="88304" page="21">n) List of Spare Parts for minimum two (2) years of Normal Operation,</Text><Text id="88305" page="21">o) Paint Colour and Specification,</Text><Text id="88306" page="21">p) Lifting / Handling Arrangements / Details,</Text><Text id="88308" page="21">r) Any other specific details required.</Text><Text id="88309" page="22">23.5 While delivery of HV Induction Motors, the documents / drawings to be submitted by Manufacturer / Vendor to KOC for records shall include but not limited to the following:</Text><Text id="88310" page="22">a) Manufacturer’s Name and Address,</Text><Text id="88311" page="22">b) Name of the Project,</Text><Text id="88312" page="22">c) Purchaser’s Order Number,</Text><Text id="88313" page="22">d) Manufacturer’s Order or Contract Number,</Text><Text id="88314" page="22">e) Manufacturer’s Drawing Number with Revision Number &amp; Dates,</Text><Text id="88316" page="22">g) Detailed Drawings showing General Arrangements with Dimensions, Weight and all other Details such as Arrangement of Terminal Boxes, Lifting Points etc. (as applicable),</Text><Text id="88317" page="22">h) Mounting Dimensions with Fixing Details,</Text><Text id="88319" page="22">j) Bearing Type and Lubrication Information (as applicable),</Text><Text id="88320" page="22">k) Terminal Boxes Dimensional Details,</Text><Text id="88321" page="22">l) Details of Temperature Detectors and other Instrumentation Sensors / Items used with all Technical Details, Type, Serial Number etc. (as applicable),</Text><Text id="88322" page="22">m) Cable Termination and Entry Positions Details,</Text><Text id="88324" page="22">o) Manuals for Installation, Testing &amp; Commissioning, Operation, Maintenance (including Periodical Maintenance Schedule) etc. and Procedures for Short Term &amp; Long Term Storage,</Text><Text id="88325" page="22">p) Average Torque Vs Speed Curve during Starting at Rated Voltage and 80 % of Rated Voltage,</Text><Text id="88326" page="22">q) Current Vs Speed Curve during Starting and various specified loads at Rated Voltage and 80 % of Rated Voltage,</Text><Text id="88327" page="22">r) Torsional Vibration Analysis Report (as applicable),</Text><Text id="88328" page="22">s) Schematic Diagrams of Auxiliary Subsystems (e.g. Lube Oil System) as applicable,</Text><Text id="88330" page="23">u) List of Special Tools,</Text><Text id="88331" page="23">v) List of Spare Parts for two (2) years of Normal Operation,</Text><Text id="88333" page="23">x) Lifting / Handling Arrangements / Details,</Text><Text id="88335" page="23">z) Reports of Type / Routine / Performance Tests and Special Tests (if any) carried out at Manufacturer’s Facility,</Text><Text id="88336" page="23">aa) Evidence of Quality Checks carried out by Manufacturer, ab) Any other data / details as specified in the Project Documents / Datasheet.</Text><Text id="88337" page="23">23.6 For detailed information on packing, marking and documentation, refer to KOC-G-004 “KOC Standard for Packing, Marking and Documentation”.</Text><Text id="88338" page="23">24.1 The motor spare parts list required for a minimum period of two (2) years of operation shall be provided.</Text><Text id="88339" page="23">24.2 For spare parts and maintenance requirements, KOC-G-009 “KOC Standard for Spare Parts and Maintenance Data” shall be referred for guidance.</Text><Text id="88341" page="28">The draft of this document “KOC Standard for High Voltage Induction Motors” (KOC-E-001, Rev. 3) has been circulated to KOC User Teams for their review &amp; comments and the responses received were suitably resolved and incorporated into the document.</Text><Text id="88342" page="28">The Team Leader Standards (Chairman-STC) would like to thank the KOC User Teams, STC Members and Task Force Members for providing Technical Inputs and Valuable Comments for the successful revision of this document.</Text><Text id="88345" page="2">28-08-2019 Issued as KOC Standard 3 Task Force (TF-E001!R3) Issued as KOC Standard FEB. 1994 2 Task Force M.llyas Prepared by Rev. Date Description Team Leader Standards Tel. 76180 TF Leader! TPL. SPL. I Standards Tel. 76070</Text><Text id="88346" page="24">KUWAIT OIL COMPANY (K.S.C.) DATASHEET NO.: REV. DATASHEET FOR HIGH VOLTAGE INDUCTION MOTOR PAGE No.: A INFORMATION / DESIGN DATA - TO BE COMPLETED BY PURCHASER GENERAL INFORMATION / DESIGN DATA KOC-E-001 1 APPLICABLE KOC STANDARD 2 IEC 60034 APPLICABLE INTERNATIONAL STANDARD TEMPERATURE 3 SERVICE CONDITIONS RELATIVE HUMIDITY INSTALLATION LOCATION / SITE 4 ALTITUDE 5 DRIVEN LOAD / EQUIPMENT 6 7 DRIVEN LOAD INERTIA (Kg.m 2 ) DIRECT VEE BELT GEAR BOX 8 DRIVE MECHANISM 3.3 kV 11 kV RATED VOLTAGE _____ kV RATED FREQUENCY 50 Hz 9 POWER SUPPLY SYSTEM THREE (3) No. OF PHASES SOLIDLY EARTHED IMPEDANCE EARTHED NEUTRAL 10 PROSPECTIVE SYSTEM FAULT CURRENT 11 POWER FREQUENCY WITHSTAND VOLTAGE 12 IMPULSE VOLTAGE WITHSTAND LEVEL REQUIRED NOT REQUIRED 13 DIFFERENTIAL PROTECTION REQUIREMENT DUTY TYPE 14 HAZARDOUS NON- HAZARDOUS 15 INSTALLATION AREA ZONE 2 ZONE 1 16 HAZARDOUS AREA CLASSIFICATION 17 GAS GROUP 18 HAZARDOUS AREA CERTIFICATION, PROTECTION TYPE &amp; TEMPERATURE CLASS 19 INSULATION CLASS &amp; ALLOWABLE TEMPERATURE RISE INGRESS PROTECTION 20</Text><Text id="88347" page="25">INFORMATION / DESIGN DATA - TO BE COMPLETED BY PURCHASER A CONTD… 21 COOLING METHOD WINDING CONNECTION 22 METHOD OF STARTING 23 24 ___________ % PERMISSIBLE VOLTAGE DROP AT STARTING 25 STARTING CURRENT No. OF STARTS PER HOUR 26 27 MOTOR EFFICIENCY MOTOR POWER FACTOR 28 HORIZONTAL VERTICAL MOTOR MOUNTING TYPE 29 30 COUPLING TYPE ANTI-CW CW 31 DIRECTION OF ROTATION SEEN FROM DRIVE END (DE) 32 WINDING TEMPERATURE DETECTOR Nos. &amp; TYPE 33 BEARING TEMPERATURE DETECTOR Nos. &amp; TYPE 34 RESISTANCE TEMPERATURE DETECTOR MATERIAL NOT REQUIRED REQUIRED 35 LOCAL BEARING TEMPERATURE INDICATOR NOT REQUIRED REQUIRED 36 BEARING VIBRATION MONITOR 37 ANTI-CONDENSATION HEATER VOLTAGE RIGHT SIDE LEFT SIDE 38 MAIN TERMINAL BOX (POWER CABLE) MOUNTING (VIEWED FROM DE) SIDE BOTTOM CABLE ENTRY POSITION 39 TOP REQUIRED NOT REQUIRED 40 AUXILIARY TERMINAL BOXES OVER-VOLTAGE PROTECTION TERMINAL MARKING DETAILS 41 CABLE GLAND TYPE 42 43 SIZE (mm 2 ) CABLE DETAILS TYPE CORES MOTOR 43 (a) 43 (b) ANTI-CONDENSATION HEATER 43 (c) INSTRUMENTATION 44 EARTHING CABLE SIZE NOISE LEVEL 45 MOTOR PAINTING COLOUR 46 REQUIRED NOT REQUIRED HEAT RUN TEST 47 ANY OTHER SPECIFIC TESTS (SPECIFY) 48 49 ANY SPECIFIC DOCUMENTATION REQUIREMENTS</Text><Text id="88348" page="26">DETAILS TO BE FURNISHED BY THE MANUFACTURER B 1 NAME OF MANUFACTURER 2 COUNTRY OF MANUFACTURE 3 MANUFACTURER&apos;S TYPE DESIGNATION 4 APPLICABLE INTERNATIONAL STANDARD 5 FRAME SIZE 6 ___________ kW RATED OUTPUT 7 ___________ VOLTS RATED VOLTAGE 8 ___________ AMPS. RATED CURRENT 9 ___________ RATED POWER FACTOR 10 INGRESS PROTECTION 11 HAZARDOUS AREA PROTECTION TYPE 12 HAC CERTIFYING AUTHORITY AND CERTIFICATE No. &amp; DATE 13 INSULATION CLASS 14 TEMPERATURE RISE CLASS 15 ___________ RPM FULL LOAD SPEED 16 ___________ AMPS. FULL LOAD CURRENT 17 ___________ AMPS. LOCKED ROTOR CURRENT 18 _____________ NM / RPM FULL LOAD TORQUE 19 _____________ NM / RPM LOCKED ROTOR TORQUE 20 _____________ NM / RPM PULL-UP TORQUE 21 _____________ NM / RPM PULL-OUT TORQUE 22 SPEED - TORQUE CHARACTERISTIC 22 (a) AT 100 % RATED VOLTAGE 22 (b) AT 80 % RATED VOLTAGE HALF LOAD 100 % LOAD ¾ LOAD 23 EFFICIENCY HALF LOAD 100 % LOAD ¾ LOAD 24 POWER FACTOR (AT VARIOUS % LOAD) 25 STATOR WINDING CONNECTION 26 No. OF STATOR WINDING TERMINALS 27 NO YES MOTOR ROTATION REVERSIBLE 28 UNI-DIRECTIONAL BI-DIRECTIONAL MOTOR FAN</Text><Text id="88349" page="27">DETAILS TO BE FURNISHED BY THE MANUFACTURER B CONTD… 29 WINDING TEMPERATURE DETECTOR Nos. &amp; TYPE 30 BEARING DETAILS 30 (a) TYPE 30 (b) MAKE, SERIES, SIZE &amp; No. 30 (c) METHOD OF LUBRICATION 30 (d) LUBRICATION INTERVALS 30 (e) TEMPERATURE DETECTOR Nos. &amp; TYPE 30 (f) LOCAL TEMPERATURE INDICATOR 30 (g) BEARING VIBRATION MONITOR 31 TERMINAL BOX: TYPE, MOUNTING ARRANGEMENT, CABLE GLAND DETAILS 32 TERMINAL BOX FAULT RATING 33 TERMINAL MARKING DETAILS 34 ANTI-CONDENSATION HEATER RATING 35 NOISE LEVEL AT ONE (1) METRE AT NO LOAD 36 TYPE TEST CERTIFICATE REF. No. AND DETAILS 37 ROUTINE TEST REPORTS 38 SPECIAL TEST REPORTS, IF ANY 39 ANY SPECIFIC DOCUMENTATION YES COMPLIANCE WITH SPECIFICATIONS / DATASHEET 40 NO (If ‘NO’ submit details in a separate sheet)</Text></Spec>