<?xml version="1.0" encoding="utf-8"?>
<Spec id="625" path="\d\c\dc493e864df4d8d26d73ae10e3b76134.pdf"><Text id="89620" page="1">Type: ZSE 12 HP-PH - 40D Machine number: 06080 Order number: N-40136146 Customer: Next Pharma</Text><Text id="89622" page="1">The document is project-dependent. It may be neither copied nor reproduced nor used in any other way without the written permission of Leistritz Extrusionstechnik GmbH.</Text><Text id="89623" page="2">This document has been created, reviewed and approved by:</Text><Text id="89625" page="4">This document describes functional design of the software installed on an IPC the pharma extrusion line ZSE 12 HP-PH - 40D</Text><Text id="89626" page="4">The machine number 06080 is a pharma extruder type ZSE 12 HP-PH - 40D which has a screw diameter of 12 mm and a process length of 40 D (in 5D increments). The ZSE12 is a co-rotating intermeshing twin screw extruder. The processing system is modular and consists of individual barrel segments in a compact cylinder. Each barrel segment has its own heating/cooling temperature control with PT100 sensors sending the meas- ured value to the controller. The system uses heating cartridges combined with water cooling via bores in the barrel supplied by the cool- ing water media supply from the customer.</Text><Text id="89627" page="4">The following equipment is connected with the extruder: � RX9100 Heating cooling unit zones BR-018-H1-K012-AE-FDA � RX3000 Dosing unit MiniTwin MT-S-HD, Brabender � RX4000 Liquid dosing Watson Marlow 120U/DV with pump head 114 � RX6000 Cooling belt MFB18-24VDC-BLE2-50.5-500, fedotec</Text><Text id="89628" page="4">The extruder together with the additional (peripheral) equipment is called extrusion line.</Text><Text id="89629" page="4">The equipment / peripheries are controlled by an automation system comprising of a Siemens S7 PLC (TIA Portal) and a COPA DATA SCADA system (zenon), which is 21 CFR Part 11 / EU GMP annex 11 compliant. The zenon SCADA system is installed on an IPC with all necessary software packages and licenses by Leistritz.</Text><Text id="89630" page="4">The following peripheries have their own control panel: � RX9100 � RX4000</Text><Text id="89631" page="4">At these panels it is possible to set values, read errors / alarms and set settings. The description of the alarms and values, which were send to the extruder SCADA system, are described in the alarm list and the unit list.</Text><Text id="89632" page="4">Note: In principle, a panel called OP S can also be provided for dosing unit RX3000. However, this is not included in the scope of delivery.</Text><Text id="89633" page="4">For detailed description of the software structure, connections and functions please refer to SDS and HDS.</Text><Text id="89634" page="4">The system differentiates two interlocking modes, “Cleaning” and “Production”. An active interlock means, that a component is locked and will be directly switched off. A switching on of an interlocked unit is not possible. The interlock mode does not affect alarms and warnings, they are generated at any time in accord- ance with the alarm list. All interlocks are described in the document Interlocking matrix.</Text><Text id="89635" page="5">Cleaning mode: This interlocking mode is used for cleaning and maintenance of the extruder. Almost all components could be switched on and off independently. Only safety relevant interlocks are active.</Text><Text id="89636" page="5">Production mode: This mode is used for manufacturing of product / batch production. The switching on / off of the components will be controlled in a logical way. For example, the dosing could only be switched on, if the main drive is running. Additionally, the safety relevant interlocks are active.</Text><Text id="89637" page="5">3.2 Operating modes The individual components of the system can be operated either in manual mode or in automatic mode.</Text><Text id="89638" page="5">Manual mode: During the manual mode the operator can control the extruder units manually. To do this, he must set the individual components to manual mode via the respective faceplate. He can switch units on or off and can change set values. In manual operation (e.g. for a test operation) of the Extruder it is not possible to record a manual batch.</Text><Text id="89639" page="5">Automatic mode: The automatic mode simplifies the operating of the extruder and takes care of the start-up sequence for the operators. During automatic mode, the extruder components are controlled automatically by the extruder PLC. Set points are set based on the recipe parameters and control is performed according to the production sequence. At sequence start the operator has to set all extruder components into automatic mode. A subse- quent switchover of a component to manual mode is permitted and is recorded in the audit trail. After the start-up steps the sequence goes into the production step and starts the batch recording.</Text><Text id="89640" page="5">Pause: During the start-up steps, the sequence can be switched into “Auto Pause” by an operator. No units are switched off by this operation. Only the switching into next step will be interrupted (e.g. the jump from Start- up 1 to Start-up 2). Already started timers will be stopped by the “Auto Pause” function.</Text><Text id="89641" page="5">Auto Emptying: The system jumps from the active step to the “Empty Step”. This means that the dosing units will be switched off. The main drive will be still running. The Empty step ends by a torque value of the main drive lower the LOLO value for the extruder load or a time step. Also, the switch-off of the main drive will finish the “Empty Step”. Alarms of the category “Error Abort” (see following chapter) will also end the sequence via the “Empty Step”.</Text><Text id="89642" page="5">After an emergency stop is pressed (regardless at which device of the extrusion line), the main drive, the heat exchanger, the dosing unit and the drum cooler will be switched off. The PLC and the SCADA system are left on. A corresponding message will be generated by the SCADA system and will be shown on the visualization.</Text><Text id="89643" page="6">The system alarms are divided in two categories: “Warning” and “Abort”. In interlocking mode “Production”, all lined up alarms will be signaled over flashlight and horn in addition to the basic display on the HMI. In cleaning mode, the horn will be disabled. All alarms and warnings and the corresponding activation conditions are defined in the document alarm list.</Text><Text id="89644" page="6">Warning: A warning message has no effect to the process. The operator will only be informed over the issue. No units will be switched off with a warning message.</Text><Text id="89645" page="6">Alarm / error abort: This fault is so critical that the system must be switched into a predefined state. This also includes communi- cation failure or the pressing of an emergency stop. If an “Error Abort” fault occurs with active automatic sequence, the system leaves the active step and switches into the &quot;Empty&quot; step. If possible, the emptying of the extruder will be done automatically. After that, the units will be switched off. If the main drive is stopped by the alarm, the emptying of the Extruder is not possible. The sequence goes directly in initial state.</Text><Text id="89646" page="6">The batch run will be controlled through an automatic sequence by a recipe. This sequence triggers all units and drives. The sequence of the extruder runs only in single batch operation. (please refer to production mode)</Text><Text id="89647" page="6">Batch start: After heating up of the extruder and the startup steps in automatic mode, a popup for input of the batch data will be displayed. On this popup the operator must enter the batch name, product name and product number for the batch run and he must push the button “OK” to start the “Production” step. With start of the automatic step “Production” a batch recording will be started.</Text><Text id="89648" page="6">Batch end: The automatic process will be finished via “Empty” step. The Empty step ends by a torque value of the main drive lower the LOLO value for the extruder load or a time step. The “Empty” step could be reached via error abort or via operator switch off. With end of the automatic sequence, the operator has to end the batch recording manually.</Text><Text id="89649" page="6">For collecting and archiving of values zenon integrated reporting system will be used. All recorded values can be viewed and selected on a trend picture on the SCADA-System. The in zenon integrated reporting system supports with the documentation, analyzation and presentation of process data, based on online- and historical data. The report viewer is used for displaying and printing batch records, recipe-, alarm and audit trail data. The report definition file, existing of several Datasets is created and configured in the editor and cannot be changed during runtime.</Text><Text id="89650" page="7">For the data integrity an Audit-Trail will be used in the SCADA-System. All events will be stored. The audit trail can be used to trace, log and archive who set/did what in the software and when including set values.</Text><Text id="89651" page="7">The zenon user administration has been created to meet all necessary requirements of the FDA (Food and Drug Administration, 21 CFR Part 11) and EU GMP annex 11. User login is to be made by the login button in the head region of the screen. After entering the username and the personnel password access will be allowed according to the existing user rights of the SCADA. The user management concept defines which different users can receive which different rights for user ac- cess, user level and function permissions. User and User groups can be managed. The desired password rules (password length, life etc.) are binding to all users. For each user different access privileges can be assigned. In this project 9 different access rights are available, please refer to SDS for description of the access rights.</Text><Text id="89653" page="1">Date Version Change/Addition 21.08.2025 1.0 Final</Text><Text id="89655" page="2">Name Signature Date Created: Anne Retsch Qualification Engineer Leistritz Extrusionstechnik GmbH</Text><Text id="89661" page="7">Abkürzung Beschreibung ARL Alarm List FDA U.S. Food &amp; Drug Administration FDS Functional Design Specification GMP Good manufacturing practice HDS Hardware dsign specification HMI Human machine interface LMX Interlock Matrix LOLO Lowlow (alarm) PLC Programmable Logic Controller SCADA Supervisory Control and Data Acquisition SDS Software design specification TIA Totally Integrated Automation Portal UNL Unit List</Text><Text id="89663" page="8">Document Number Version Title BZ 40136146PI010 A PID Extruder 06080 N 40136146-01 01 Order confirmation ARL_6080 01 Alarm list Pharma Extrusion line ZSE 12 HP-PH - 40D, machine number 06080 UNL_6080 01 Unit list Pharma Extrusion line ZSE 12 HP-PH - 40D, machine number 06080 LMX_6080 01 Interlock Matrix Pharma Extrusion line ZSE 12 HP-PH - 40D, machine number 06080 SDS_6080 01 SDS Pharma Extrusion line ZSE 12 HP-PH - 40D, machine number 06080 HDS_6080 01 HDS Pharma Extrusion line ZSE 12 HP-PH - 40D, machine number 06080</Text></Spec>